E-200

Type:
Communication
Usage:
-
E-200

Description

 

Parameters:

 Intercom line:  
 Impedance:    220 Ω AC
 4700 Ω DC
     
 Nominal/maxinum level:    -10 dBu / +3 dBu
       
 Frequency response:    100 Hz - 10 KHz (-3 dB)
 System
 specification :
 
 Voltage operation :    +12 to +30 VDC  
       
 Dynamic range:    80 dB  
       
 Bringing impedance @ 1KHz:    > 20 KΩ  
       
 Side-Tone cancellation:    Adjustable from 0 to 30 dB @ 1 KHz  
       
 Microphone limiter:    Range: 28 dB  
       
 Maximum cable length:    500-2000 mts, Depends on istallation  
       
 Recommended wire type    Shielded mic cable: 2 x 0,30mm2  
       
 Call signal    +2,8 mA / 11 VDC  
       
 Call threshold    3 VDC  
       
 Remote mic-off    Power Interruption: 100 ms  
       
 Remote buzz-off    Automatic, headset priority  
 Reampliefier:  
 Microphone type:    Dynamic or electret 
 dynamic only on ES-200
     
 Iput impedance:    4k7Ω
       
 Nominal/max level :    -45 dBu (H) / -20 dBu (L)
     
 Limiter range:    28 dB
     
 Presence filter:    +6 dBu @ 4700 Hz
     
 Phantom voltage:    +9 VDC (internal preset)
     
 Microphone selection
 (ES-200):
   Automatic, headset priority
 Headset
 amplifier:
 
 Impedance:    200 Ω (nominal), 2 KΩ max  
       
 Maximum level:    20 Vpp (200 Ω)  
       
 Output power:    250 mW (200 Ω)  
       
 Frequency response:    250 Hz - 15 KHz  
       
 Residual noise:    -100 dBu (all mic-off)  
 Loudspeaker
 amplifier
 (ES-200):
 
 Impedance:    16 Ω
     
 Output power:    1,25 Watt
       
 Loudspeaker selection:    Automatic, headset priority
 P.A. out:  
 Type:    Balanced by XLR  
       
 Output impedance:    100 Ω  
       
 Output level:    +4 dBu (nominal) / +8 dBu (max)  
 Program input:  
 Type:    Balanced by XLR
     
 Impedance (line/mic):    40 KΩ / 2 KΩ
       
 Input level:    Mic:  adjustable -15 dBu to -45 dBu
 Line: adjustable +10 dBu to -20 dBu
 P.A. relay
 (EF-200)
 
 Connections:    1 NO + 1 NC circuit / JACK 1/4  
       
 Contacts:    0,5 Amp @ 125 VAC / 1 Amp @ 30 VDC  
       
 Relay activaction :    By PA, micon A/B, or buzzer mute keys  
 Multichannel
 operation:
 
 System cabling :    Master-slave link
 with standard RJ-45 (8)
     
 Channels::    Maximum recommended: 10 (5 stations)
 Interface
 4W2-200:
 
 3, 4 Wire mode,
 Z/nominal level:
   Rx: > 2 KΩ / -45 dBu to +10 dBu
 Tx: < 600 Ω / +10 dBu to -60 dBu
 
       
 2 Wire mode
 (Telephone line):
   Zterm: adjustable 220 Ω to 1k2 Ω  
 Headset AM-100
 AM-100/2
 
 Microphone:    Dynamic, cardioid, 200 Ω
     
 Headphone:    Dynamic, 400 Ω each muff
       
 Termination:    XLR-4. 1,5 mts steel cable
 Power supply:  
 Mains voltage :    90-264 VAC / 50-60 Hz / 50 VA max  
       
 Power supply (EF-200):    24 VDC nominal / 1,8 Amps  
       
 Protections:    Short-circuit on the line, overheat  
       
 DC current (ES-200):    40 ma / 120 ma  
       
 DC current
 (EM-201, 4W2-200):
   30 ma / 60 ma  
 Emergency
 supply:
 
 Battery type:    Alkaline 9 V (near panel compartment)
     
 Emergency system
 operation:
   12 VDC / 500 mA max
       
 Emergency intervals:    10 minutes to auto switch-off
     
 Estimate battery life:    1 hour (4 beltpack system)
 Accessories:  
 Program Input transformer:    Ref: TDA -I  
       
 P.A. out transformer:    Ref: TDA-O  
       
 Plastic security cover:    Ref: TP-1  
       
 Metal, key protected cover:    Ref: TPS-1  
 Dimensios
 and weight:
 

 

/