Intercom line: |
|
Impedance: |
|
220 Ω AC
4700 Ω DC |
|
|
|
Nominal/maxinum level: |
|
-10 dBu / +3 dBu |
|
|
|
|
Frequency response: |
|
100 Hz - 10 KHz (-3 dB) |
|
System
specification : |
|
Voltage operation : |
|
+12 to +30 VDC |
|
|
|
|
|
Dynamic range: |
|
80 dB |
|
|
|
|
|
Bringing impedance @ 1KHz: |
|
> 20 KΩ |
|
|
|
|
|
Side-Tone cancellation: |
|
Adjustable from 0 to 30 dB @ 1 KHz |
|
|
|
|
|
Microphone limiter: |
|
Range: 28 dB |
|
|
|
|
|
Maximum cable length: |
|
500-2000 mts, Depends on istallation |
|
|
|
|
|
Recommended wire type |
|
Shielded mic cable: 2 x 0,30mm2 |
|
|
|
|
|
Call signal |
|
+2,8 mA / 11 VDC |
|
|
|
|
|
Call threshold |
|
3 VDC |
|
|
|
|
|
Remote mic-off |
|
Power Interruption: 100 ms |
|
|
|
|
|
Remote buzz-off |
|
Automatic, headset priority |
|
|
Reampliefier: |
|
Microphone type: |
|
Dynamic or electret
dynamic only on ES-200 |
|
|
|
Iput impedance: |
|
4k7Ω |
|
|
|
|
Nominal/max level : |
|
-45 dBu (H) / -20 dBu (L) |
|
|
|
Limiter range: |
|
28 dB |
|
|
|
Presence filter: |
|
+6 dBu @ 4700 Hz |
|
|
|
Phantom voltage: |
|
+9 VDC (internal preset) |
|
|
|
Microphone selection
(ES-200): |
|
Automatic, headset priority |
|
Headset
amplifier: |
|
Impedance: |
|
200 Ω (nominal), 2 KΩ max |
|
|
|
|
|
Maximum level: |
|
20 Vpp (200 Ω) |
|
|
|
|
|
Output power: |
|
250 mW (200 Ω) |
|
|
|
|
|
Frequency response: |
|
250 Hz - 15 KHz |
|
|
|
|
|
Residual noise: |
|
-100 dBu (all mic-off) |
|
|
Loudspeaker
amplifier
(ES-200): |
|
Impedance: |
|
16 Ω |
|
|
|
Output power: |
|
1,25 Watt |
|
|
|
|
Loudspeaker selection: |
|
Automatic, headset priority |
|
P.A. out: |
|
Type: |
|
Balanced by XLR |
|
|
|
|
|
Output impedance: |
|
100 Ω |
|
|
|
|
|
Output level: |
|
+4 dBu (nominal) / +8 dBu (max) |
|
|
Program input: |
|
Type: |
|
Balanced by XLR |
|
|
|
Impedance (line/mic): |
|
40 KΩ / 2 KΩ |
|
|
|
|
Input level: |
|
Mic: adjustable -15 dBu to -45 dBu
Line: adjustable +10 dBu to -20 dBu |
|
P.A. relay
(EF-200) |
|
Connections: |
|
1 NO + 1 NC circuit / JACK 1/4 |
|
|
|
|
|
Contacts: |
|
0,5 Amp @ 125 VAC / 1 Amp @ 30 VDC |
|
|
|
|
|
Relay activaction : |
|
By PA, micon A/B, or buzzer mute keys |
|
|
Multichannel
operation: |
|
System cabling : |
|
Master-slave link
with standard RJ-45 (8) |
|
|
|
Channels:: |
|
Maximum recommended: 10 (5 stations) |
|
Interface
4W2-200: |
|
3, 4 Wire mode,
Z/nominal level: |
|
Rx: > 2 KΩ / -45 dBu to +10 dBu
Tx: < 600 Ω / +10 dBu to -60 dBu |
|
|
|
|
|
2 Wire mode
(Telephone line): |
|
Zterm: adjustable 220 Ω to 1k2 Ω |
|
|
Headset AM-100
AM-100/2 |
|
Microphone: |
|
Dynamic, cardioid, 200 Ω |
|
|
|
Headphone: |
|
Dynamic, 400 Ω each muff |
|
|
|
|
Termination: |
|
XLR-4. 1,5 mts steel cable |
|
Power supply: |
|
Mains voltage : |
|
90-264 VAC / 50-60 Hz / 50 VA max |
|
|
|
|
|
Power supply (EF-200): |
|
24 VDC nominal / 1,8 Amps |
|
|
|
|
|
Protections: |
|
Short-circuit on the line, overheat |
|
|
|
|
|
DC current (ES-200): |
|
40 ma / 120 ma |
|
|
|
|
|
DC current
(EM-201, 4W2-200): |
|
30 ma / 60 ma |
|
|
Emergency
supply: |
|
Battery type: |
|
Alkaline 9 V (near panel compartment) |
|
|
|
Emergency system
operation: |
|
12 VDC / 500 mA max |
|
|
|
|
Emergency intervals: |
|
10 minutes to auto switch-off |
|
|
|
Estimate battery life: |
|
1 hour (4 beltpack system) |
|
Accessories: |
|
Program Input transformer: |
|
Ref: TDA -I |
|
|
|
|
|
P.A. out transformer: |
|
Ref: TDA-O |
|
|
|
|
|
Plastic security cover: |
|
Ref: TP-1 |
|
|
|
|
|
Metal, key protected cover: |
|
Ref: TPS-1 |
|
|
Dimensios
and weight: |
|
|